A Ray's company - serving Enterprise, NV

Rheem Heating & Furnace in Enterprise, NV

Furnace & heatingFurnace & heating
AC repairAC repair
Heat pumpsHeat pumps
Ductless mini splitsDuctless mini splits
CarrierCarrier
TraneTrane
GoodmanGoodman
Every visit starts with

Seasonal tune-up and full diagnostic on your Carrier, Trane, or Goodman system - readings shown to you before any repair is proposed

We have financing partners for your new heating and cooling system*On approved credit; ask us about your options

Diagnosis first, numbers second - you approve the repair price before a single part goes in.

Get your free estimate

Rheem Heating & Furnace in Enterprise: What to Know First

We handle Rheem heating and furnace work in Enterprise as an independent Rheem service provider, and most furnace repairs here are a single visit – we come out, run the readings, and you see the numbers before anyone picks up a wrench. Furnace repair in Enterprise usually runs $150 to $700 depending on the part, and a full system replacement is a scheduled job, not a same-day one, because a furnace has to be sized to the house. We don’t do phone quotes that change at the door. You call, we show up, we test, and you get a real number, no surprises.

Call (844) 455-2034

This page is for the homeowner with a Rheem furnace, air handler, or packaged unit already in the house – maybe it came with the place, maybe you had it put in a few years back – and now it’s acting up. Call (844) 455-2034 and a live person picks up, day or night. That’s the whole pitch.

How Rheem Products Fail – and How We Fix Them

Rheem builds solid equipment, but every brand has its habits, and Rheem’s show up in specific places. Here’s what we actually see in Enterprise homes.

  • Rheem Classic and Classic Plus gas furnaces – the hot surface ignitor. These units use a silicon nitride ignitor that lives right in the gas stream, and around here it’s the single most common no-heat call we get. You’ll hear the draft inducer start, then nothing – no ignition, no flame, just a blower running cold. The ignitor cracks from heat cycling and dust. We test it with a meter before replacing, then swap in the OEM part, because a cheap aftermarket ignitor on a Rheem Classic tends to fail again inside a season.
  • Rheem RGRL and RGTK series – the in-shot burners and flame sensor. When a Rheem furnace short-cycles – lights, runs a minute, shuts off – it’s often a dirty flame sensor or burners that need cleaning, not a control board. The flame sensor is a $15 part that too many outfits turn into a $600 board replacement. We clean and test first. Readings first, numbers second.
  • Rheem Prestige and Achiever series – the induced draft blower. On older Prestige and Achiever furnaces, the draft inducer motor bearings wear and you get a rumble or a squeal at startup, sometimes a pressure switch fault that looks electrical but isn’t. We check the pressure switch tubing and the inducer before chasing the board. A lot of “bad board” diagnoses on these units are actually a tired inducer.
  • Rheem gas valves on high-efficiency condensing furnaces. The condensing units – the ones with PVC flue pipe – pull a gas valve that can stick or drift on the manifold pressure over time. Symptoms are weak flame, delayed ignition, or a furnace that runs but won’t heat the house on a cold night. We measure manifold pressure with a manometer before condemning the valve. Plenty of Rheem gas valves get replaced that only needed the pressure checked and set.
  • Heat exchangers in Rheem furnaces past 15 years. This is the one that matters for safety. A cracked heat exchanger on a Rheem furnace can leak carbon monoxide into the airstream, and you won’t smell it. If you see a lazy, dancing flame, soot, or a furnace that trips the high-limit repeatedly, stop running it and call. This isn’t a DIY check. We inspect the exchanger with a camera and a combustion analyzer, and if it’s cracked, we tell you straight – repair or replace, and we show you why.
Explore

Styles & brands we work with

  • AC repair
  • Furnace & heating
  • Heat pumps
  • Ductless mini splits
  • Carrier
  • Trane
  • Goodman

Our Rheem Heating & Furnace Process

Here’s how a Rheem heating job actually goes when you call Ray’s Heating & Air Enterprise.

  1. 1
    The call. A live person answers, every time, around the clock. We ask what the furnace is doing – no heat, short-cycling, weird noise, error code on the board – and we book a real window, not a four-hour “sometime today.”
  2. 2
    Diagnostics first. The person at your door tests before touching anything. Ignitor, flame sensor, pressure switch, gas pressure, heat exchanger, all of it read with meters and gauges. You see the readings. We don’t guess at parts.
  3. 3
    The parts decision. On a Rheem, we default to OEM parts for ignitors, gas valves, and control boards because the aftermarket copies on these specific components don’t hold up. For things like blower motors and capacitors, a quality aftermarket part is fine and saves you money. We tell you which is which and why, and you decide.
  4. 4
    The repair. We do the work, then we run the furnace through a full heat cycle – startup, steady burn, shutdown – and watch the flame and the readings the whole way. If it doesn’t hit spec, it’s not done.
  5. 5
    The guarantee. Every heating and cooling job carries our 90-Day Done Right Promise in writing. If it’s not right, one call brings Ray back – no hassle, no argument.
Before & after

See the difference

Before - Recent ProjectBeforeAfter - Recent ProjectAfter
Recent Project
Before - Full RestorationBeforeAfter - Full RestorationAfter
Full Restoration
Before - Complete UpgradeBeforeAfter - Complete UpgradeAfter
Complete Upgrade

What Rheem Heating & Furnace Costs in Enterprise

Real numbers, grounded in what we actually charge and what the parts actually cost. What moves the price is the part and how deep we have to go to reach it – an ignitor swap is a quick job, a gas valve is more involved, and a cracked heat exchanger is a different conversation entirely.

Rheem job Typical range in Enterprise
Furnace repair (ignitor, flame sensor, gas valve, blower) $150 – $700
Furnace tune-up and safety check $80 – $200
Furnace replacement (sized and scheduled) $3,500 – $7,500
AC repair, if your Rheem system shares the air handler $150 – $650

Furnace tune-ups run $80 to $200, and on a Rheem we clean the burners, test the ignitor and flame sensor, check the heat exchanger, and leave you a written report of what we found. The estimate is always free, and if you have a written estimate from someone else, our second opinion on it is free too.

Why Enterprise Homeowners Call Ray’s Heating & Air Enterprise for Rheem Work

Because the person who shows up actually knows a Rheem, and because you’ll see him again. Ray Alvarez has been doing this since 2002, right here in the area, with his name, address, and license number published for anyone to check. He answers his own phone at two in the morning. The technicians are background-checked and uniformed, and the same face comes back – not a rotating crew who’ve never seen your furnace. Every job is backed by the 90-Day Done Right Promise in writing. We service all the major brands too – Carrier, Trane, Lennox, Goodman, York, Daikin, Bryant, American Standard – so if your Rheem has a cousin in the garage, we speak that language as well. No trip charge inside the county, and a 10% discount for seniors and veterans. That’s why folks in Enterprise keep our number on the fridge.

FAQs

Need HVAC help nationwide? Licensed & insured · 1-hour response · free estimates
Call (844) 455-2034
Local Service Coverage

Request a Free Estimate in Enterprise

Tell us what you need - Ray's Heating & Air Enterprise responds fast. No obligation.

By submitting this form you agree to our Privacy Policy and consent to be contacted by phone, email or SMS about your request, including by local professionals who may handle it.

Prefer to text? Text Now
Call Now - 24/7 Dispatch